Working principle

Screenshot 2025-12-08 3.15.59 PM.png

Installation guide

Screenshot 2025-12-11 4.58.10 PM.png

User guide

Screenshot 2025-12-08 3.12.00 PM.png

Download translated
document

Screenshot 2025-12-12 3.12.20 PM.png

Exploded view

Working principle

Working principle

Screenshot 2025-12-11 1.30.12 PM.png
Screenshot 2025-12-11 3.41.36 PM.png
Installation

Installation procedure

STEP 1 - Connections

Screenshot 2025-12-11 4.33.53 PM.png

Water supply

3/4 inch PVC external thread - Preferably use potable
quality tap water - (minimum supply pressure 1.5 bar) -
Especially NO well water and NO rainwater

Screenshot 2025-12-11 4.34.21 PM.png

Power supply

230 V European socket - Provide an earthed
socket with fuse

Screenshot 2025-12-11 4.34.48 PM.png

Drainage 

PE pipe diameter 6/4 mm (free flow)
-In the sewer
-At the rainwater well
-To the buffer tank
- To the swimming pool (connect after the filtration pump to the pressure pipe with
return

Screenshot 2025-12-11 4.35.36 PM.png

Hydrogen evacuation

PVC valve diameter 32 mm (towards outside air, as high as possible)
- still in a “slightly” upward trend
- use only 45° elbows

STEP 2 - Starting

- Fill the salt tank (max.25 kg)

- Open the water supply

- Switch on the power

Screenshot 2025-12-11 4.52.07 PM.png

Press "START" (green button held down for 5seconds)
on the home screen and select your language.
The system will automatically refill all levels (approximately 1 hour later),
ready to produce chlorine

STEP 3 - pH/Rx measuring chamber

- Connect the water supply and drain

- Place the measuring pH & Rx probes

- Ensure watercirculation

-Test the water supply before and after the pump

(Allow the measuring probes to acclimate for at least 1 hour before calibrating)

Screenshot 2025-12-11 5.04.43 PM.png

Chlorine production starts and the chlorine tank is filled in approximately 1hour

The system is ready for use!

User guide

User guide

Main screen

Screenshot 2025-12-12 1.17.32 PM.png

Language selection & START/STOP function

"key" button (code required)

(Click on the key on the picture for service settings info) 

Click on Start to go to Home Screen

Home screen

Screenshot 2025-12-12 1.17.45 PM.png

Clorine zone - Alarms and warnings

pH zone - ORP(Redox) zone

(Click on pH or ORP in the image for calibration info)

 

pH Calibration

pH Calibration screen

Screenshot 2025-12-12 1.51.19 PM.png

Procedure

- Close the water inlet and outlet of the measuring chamber

- Clean and dry the pH probe

- Place the probe in the first buffer solution pH 4
or pH 7 (the buffer used is automatically recognized)

- Press the blue button "CAL B1" (the
button turns GREEN) and the calibration starts
(approximately 1 minute)
The gray diode turns white and indicates "READY"

- Remove the probe from the buffer solution and clean it dry

- Place the probe in the buffer solution pH7 or pH 10
Press the blue button "CAL B2" (the button
turns GREEN) and the calibration starts
(approximately 1 minute)
The gray diode turns white and indicates "READY"

-Remove the probe from the buffer solution and clean it dry

- Put the probe back in the measuring chamber

- Open the measuring water supply

- The OK button appears and turns GREEN after approximately
1 minute, the dosage starts.

- The execution date appears

- Exit the calibration screen via the blue BUTTON (top left)

IMPORTANT INFORMATION

- Calibrate monthly

- Combine pH 4 and pH 7 or pH 7 and pH 10 buffer solutions

- NEVER combine buffer 4 with 10

- Replace buffer solutions every 6 months to avoid deviations

- Clean and dry the measuringprobe thoroughly before and after
using each buffer

- Calibrate at the pool's operating temperature (+/- 3°C) If the
calibration procedure is interrupted
Use the red 'RESET' button and start again

- Calibration error (indicated by'ALARM')
Use the red 'RESET' button and start again

ORP Calibration

ORP Calibration screen

Screenshot 2025-12-12 2.17.15 PM.png

Procedure


- The calibration screen appears


- Close the water inlet and outlet of the measuring chamber


- Clean and dry the Rx probe


-Place the probe in the 475 mV buffer solution
(the buffer used is automatically recognized)
Press the blue button "CAL 01"

(the button turns GREEN) and the calibration starts

(approximately 1 minute)


- The gray diode turns white and indicates "READY"

​

- Remove the probe from the buffer solution and clean it dry


- Put the probe back in the measuring chamber


- Open the measuring water supply


- The OK button appears and turns GREEN after
approximately 1 minute, the dosage starts.

 
-The execution date appears.

IMPORTANT INFORMATION

- Use 475 mV buffer solution

- Replace the buffer solution every 6 months to avoid deviations

- Clean and dry the measuring probe thoroughly
before using the buffer solution

- If the calibration procedure is interrupted
Use the red “RESET” button and start again

- Calibration error (indicated by “ALARM”)
Use the red “RESET” button and
start again

Service settings
Screenshot 2025-12-12 1.23.03 PM.png

Click on 'Key' in main menu
and use code 1234

Service menu

Screenshot 2025-12-12 1.18.04 PM.png

- Chlorine production process

- Set pH setpoint and pH Range P

- Set Redox setpoint and Redox range P

- Alarms and resets

-  Troubleshooting

- Meaning of alarms and possible causes

- Intervention instructions and possible solutions

pH settings

Screenshot 2025-12-12 2.38.39 PM.png
Screenshot 2025-12-12 2.38.56 PM.png

- Press the blue gear icon in the bottom left corner

- The bars with the setpoint and P range appear

- Press directly the numeric code of the parameter
you want to change (setpoint or P range)

- A numeric screen appears
Delete the current value with the "DEL" key

- Enter the desired value and confirm with OK

Exit the screen using the blue key in the top left corner

Redox settings

Screenshot 2025-12-12 2.43.40 PM.png

- Tap the blue circle icon in the bottom left corner
Bars with setpoint and P range are displayed
Directly press the numeric code of the
parameter you want to change (set point or P range)

- A digital screen appears.
Delete the current value using the “DEL” key

- Enter the desired value and confirm with OK

- Exit the screen using the blue button in the top left corner

The OK button will appear and turn GREEN
After about 2 minutes, the dosage starts

Alarms and resets

- Tap in the ALARM area (dark blue bar)
The list of possible alarms is displayed

- Check the indicated alarm

- Identify the cause of the problem

- Consult the intervention instructions with possible solutions

- Reset the alarm (using the blue “RESET” button)
- In case of repeated reappearance of the same critical alarm (contact the installer)

RESETTING THE OPERATING HOUR METER
(chlorineproduction)

Screenshot 2025-12-12 2.50.41 PM.png
Screenshot 2025-12-12 2.50.58 PM.png
Screenshot 2025-12-12 2.50.49 PM.png

Via maintenance code 5130
Access the main menu
Press the clock
The hour meter appears

Alarms and warning

Screenshot 2025-12-12 2.53.44 PM.png
Screenshot 2025-12-12 2.54.00 PM.png
Screenshot 2025-12-12 2.53.51 PM.png
Screenshot 2025-12-12 2.55.34 PM.png